DUKE PROOFER OVEN
RESTAURANT
EQUIPMENT
MANUAL
REVISED:
January 18, 2006
DUKE PROOFER OVEN
DUKE MANUFACTURING CO.
TOLL FREE 1-800-735-DUKE(3853)
1
-
314
-
231
-
1130
WARNING Risk of Electric Shock
INSTALLATION
Inspect the exterior of the shipping container carefully and note any damage on the delivery
receipt. Remove the shipping container and check for damage to the oven. If there is any
damage file a freight claim with the carrier and call Duke at 800-735-3853.
Compare the voltage and phase from the oven specification label to the power supply for the
oven and call Duke if there is a difference. If the phase is wrong, a qualified service
technician can change the wire connections inside the oven to correct the problem. See the
illustration on page 4 for phase conversions. If the voltage is wrong, the heat elements must
be changed. Call Duke to get new elements.
This appliance must be secured to building structure. A restraining device kit
(#153586) was provided with the unit to limit the movement of the appliance without
depending on or transmitting stress to the electrical conduit. Installation instruction is
in the kit.
This Restraining Device MUST always be connected when the Appliance is in Service.
Disconnect for movement, servicing and or cleaning, then reconnect when the
appliance has been returned to its normal position.
The appliance shall be installed using flexible conduit.
Check the swing of the door. The hinge side can be changed by following the instructions on
page 8. The door swing direction can be changed in the field after you have a new drip
channel for the proofer door. Call Duke to get the new drip channel for the proofer door.
Check the door seal and make sure both doors close completely. If they do not close and
seal properly, call Duke for assistance.
Important: A minimum clearance of 6” from the top of the unit to the ceiling must be
provided.