Duke FLEXIBLE BATCH BROILER Spécifications Page 71

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 90
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 70
Troubleshooting
Step 7 Components
Troubleshooting
Step 7 Components
Controller-See slide #74 or #79
Conveyor Motor Relay
Input Voltage Check
24 VDC across wires 30 & 31
from controller
Output Voltage Check
120 VAC across wires 4 & 5
Other Relay Tests
-With 24 VDC input there should be 120 VAC across the output
-With 0 VDC input there should be approx. 0 VAC across output
Motor Capacitor
Test: Discharge capacitor.
Resistance should measure low and drift to high ohms